STATIC
LOAD TESTING
The static load test (SLT) involves the direct measurement of pile
head displacement in the response to a physically applied test load.
It is the most fundamental form of pile load test and is considered
as the bench-mark of pile performance. Testing has been performed
in the load range 100kN to 12,000 kN. The SLT may be carried out for
the following load configurations:
- Compression
- Lateral
- Tension (i.e. uplift)
For the SLT the load is most commonly applied via a jack acting against
a reaction beam, which is restrained by an anchorage system or by
jacking up against a reaction mass (“kentledge”or dead weight). The
anchorage system may be in the form of cable anchors or reaction piles
installed into the ground to provide tension resistance. The nominated
test load is usually applied in a series of increments in accordance
with the appropriate Code, or with a pre-determined load testing specification
for a project. Each load increment is sustained for a specified time
period, or until the rate of pile movement is less than a nominated
value.
Static load testing methods are applicable to all pile types, on land
or over water, and may be carried out on either production piles or
sacrificial trial piles. Trial piles are specifically constructed
for the purpose of carrying out load tests and therefore, are commonly
loaded to failure. Testing of production piles however, is limited
to prove that a pile will perform satisfactorily at the serviceability
or design load, plus an overload to demonstrate that the pile has
some (nominated) reserve capacity.

THE
TEST PROCEDURE
Loading is applied to the test pile using a calibrated hydraulic jack, and where required a calibrated load cell measures the load.
During the SLT, direct measurements of pile displacement under the applied loading are taken by reading deflectometers (dial gauges reading to 0.01mm) that are positioned on glass reference plates cemented to the pile head. The deflectometers are supported by reference beams that are founded a specified distance away from both the test pile and any reaction points.
Although SLT is generally held as the most reliable form of load testing a pile or pile group, it is important that interaction effects are minimised. These may result from interaction between the test pile and the anchorage systems, or between the measuring system and reaction points. For this reason, careful attention is given to performing the test in accordance with proper procedures.
TEST RESULTS
Test results are presented inconventional graphical format showing the applied load versus pile head displacement.
|
|